Insulation Thickness Calculator

Find how thick each insulation material must be to reach a target U-value, or to match an existing layer, and see how much space a vacuum insulation panel (VIP) saves.

What do you want to calculate?

If left empty, only the insulation layer and the wall surface resistances (0.17 m²·K/W) are counted. Solid brick walls are often around 1.2–1.8.

Your own material (optional)

Enter mW/(m·K), e.g. 24, or W/(m·K), e.g. 0.024. The material is added to the result and can be chosen as the existing layer.

Result

Thermal resistance to add: 3.45 m²·K/W (≈ R-19.6)

Materialλ used, mW/(m·K)Thickness
VIP, building design valueAged centre-of-panel value for metallized-film VIPs over 25 years (IEA EBC Annex 39); panel edges not included 8 28 mm
Supertech fumed silica VIPDeclared initial centre-of-panel value; for appliances and cold-chain equipment 4.5 16 mm
Supertech fiberglass VIPDeclared initial centre-of-panel value (Double Alu); for appliances and cold-chain equipment 2 7 mm
PU / PIR foamTypical value 22 76 mm
XPSTypical value 32 111 mm
EPSTypical value 35 121 mm
Mineral / rock woolTypical value 40 139 mm

A VIP at the building design value needs 28 mm where mineral wool needs 139 mm — 111 mm thinner.

Thicknesses are theoretical values rounded up to the next whole millimetre. Supertech fumed silica VIPs are made 10–45 mm thick; thicker requirements are usually built up in two offset layers.

Next step

Send us the thickness and the panel area or drawing. We propose VIP series, panel sizes and layout.

Request a panel layout Compare the five VIP series

Last updated:

How the calculation works

An insulation layer adds thermal resistance R. Its thickness is d = λ × R, where λ is the material’s thermal conductivity. Halve λ and the layer needs half the thickness.

To reach a target U-value, the layer must add R = 1/Utarget − 1/Uexisting. Without an existing U-value, the calculator subtracts only the surface resistances of a wall, 0.17 m²·K/W (ISO 6946).

To match an existing layer, the calculator takes that layer’s resistance (thickness ÷ λ) and finds the thickness of every other material with the same resistance.

Which VIP value should you use?

VIP data sheets state the conductivity at the centre of a new panel. Over its service life, gas and water vapour slowly enter the envelope, and the barrier film carries some heat around the panel edges. A wall built from many panels therefore performs below the centre-of-panel value.

For building walls, roofs and floors, use the design value. IEA EBC Annex 39 cites a Swiss design value of 8 mW/(m·K) at the centre of a VIP with a metallized film envelope, allowing for about 25 years of moisture and air ingress. Panel edges come on top: for a 1.00 × 0.50 × 0.02 m panel the same report gives an effective value of about 8.7 mW/(m·K), and smaller panels or metal-foil envelopes lose more. The calculator uses 8 mW/(m·K); for a specific panel layout, add the edge effect or ask us to calculate it. The declared values are useful for comparing panels and for appliances and cold-chain equipment with large panels and controlled conditions.

Worked examples

CaseThickness needed
Interior insulation of a solid masonry wallExisting wall U ≈ 1.4 → target 0.24 W/(m²·K). Every millimetre is lost room depth.
  • VIP, building design value: 28 mm
  • PU / PIR foam: 76 mm
  • Mineral / rock wool: 139 mm
Roof terrace or balcony over a heated roomExisting slab U ≈ 1.0 → target 0.15 W/(m²·K). Door thresholds limit the build-up height.
  • VIP, building design value: 46 mm
  • PU / PIR foam: 125 mm
  • XPS: 182 mm
Cold room or freezer wall replacing 100 mm PUSame layer resistance as 100 mm PU foam; the space gained becomes storage volume.
  • VIP, building design value: 37 mm
  • Supertech fumed silica VIP: 21 mm
  • EPS: 160 mm
Appliance cabinet wall replacing 60 mm PUCentre-of-panel values; real cabinets combine VIP with foam and lose some resistance at joints.
  • Supertech fumed silica VIP: 13 mm
  • Supertech fiberglass VIP: 6 mm

Conductivity values used

MaterialTypical range, mW/(m·K)λ used, mW/(m·K)Basis
VIP, building design value≈ 88Aged centre-of-panel value for metallized-film VIPs over 25 years (IEA EBC Annex 39); panel edges not included
Supertech fumed silica VIP≤ 4.54.5Declared initial centre-of-panel value; for appliances and cold-chain equipment
Supertech fiberglass VIP2.0 ± 0.52Declared initial centre-of-panel value (Double Alu); for appliances and cold-chain equipment
PU / PIR foam20–2522Typical value
XPS30–3532Typical value
EPS33–3835Typical value
Mineral / rock wool35–4540Typical value

What this calculator does not check

  • Moisture. Interior insulation changes where condensation can form. Check the build-up with a hygrothermal assessment before installing.
  • Thermal bridges. VIP panel edges and joints, fixings, frames, slab edges and window reveals add heat loss that a one-dimensional calculation does not see.
  • Pipes and curved surfaces. The calculation is for flat layers; pipe insulation needs the cylindrical formula.
  • Regulations and fire. Required U-values and fire classes depend on the country and building type.

Related guides

Request a panel layout

Your current calculation (mode, inputs, λ values and thicknesses) is sent with this request, so you do not need to repeat it.

Drawings help us plan the layout. Email them, with your company name, to sales@vacuum-insulation-systems.com

Describe the application, the panel area or drawing dimensions, and the quantity.

Company and project details (optional)

By submitting this form you agree to the processing of your data as described in our Privacy Policy.

Frequently Asked Questions

How thick does insulation need to be for a U-value of 0.24?

It depends on λ and on the existing construction. Starting from a solid wall with U ≈ 1.4, the new layer must add about 3.45 m²·K/W: roughly 28 mm of VIP at the building design value, 76 mm of PU foam or 139 mm of mineral wool.

How much thinner is a vacuum insulation panel than PU foam?

At centre-of-panel values a VIP is 5–10 times thinner than PU foam for the same resistance. With the aged building design value of 8 mW/(m·K) it is still about 2.7 times thinner, or about 2.5 times once the panel edges are counted.

Can I cut a VIP to fit on site?

No. Cutting or drilling releases the vacuum. Panels are made to size, so the layout is planned before ordering and gaps are filled with conventional insulation.

Does the calculator work in imperial units?

The inputs are SI. The result also shows the added resistance as an imperial R-value (1 m²·K/W ≈ R-5.68).

References

  • ISO 6946 — Building components and building elements: thermal resistance and thermal transmittance, calculation methods.
  • IEA EBC Annex 39 — High Performance Thermal Insulation (HiPTI): summary report, Subtasks A and B. Design value: Table 4, p. 13; edge effect: section 4.1, p. 15.
  • ISO 16478:2023 — Thermal insulation: vacuum insulation panels (VIP), specification including ageing factors and linear edge bridges.
  • EN 17140 — Thermal insulation products for buildings: factory-made vacuum insulation panels (VIP), specification.